04 / Acceptance and handover
Prove the result under a representative production condition
Map controlling glass temperatures, challenge representative lots and verify breakage containment and response. Retain measured evidence for bottle drawing and condition classes and breakage, containment and acceptance with method, position, limit, deviation, witness, approval and revalidation trigger. Instrument representative package positions and routes, verify residence and temperature distributions, challenge stops and line gaps, measure package integrity and product quality, trend water condition and heat balance, and document accepted operating envelopes and deviation handling. Put the sample or test material, method, instrument, production state, duration, limit, witnesses, retained record and deviation authority in the protocol before testing begins. Requalify when a product, package, site, speed or connected system invalidates the accepted basis.