04 / Acceptance and handover
Prove the result under a representative production condition
Run representative fleet classes and verify rate, damage, foreign-bottle handling and safe recovery. Retain measured evidence for bottle and crate format matrix and drop, breakage and recovery proof with method, population, limit, deviation, witness, approval and lifecycle review trigger. Challenge representative contamination and defect cases, measure wash and rinse conditions, verify chemical residue and hygiene, inspect container integrity, qualify pressure or thermal performance by condition class, and reconcile returned, rejected, replenished and released fleet quantities. Put the sample or test material, method, instrument, production state, duration, limit, witnesses, retained record and deviation authority in the protocol before testing begins. Requalify when a product, package, site, speed or connected system invalidates the accepted basis.