04 / Acceptance and handover
Prove the result under a representative production condition
Use approved defect samples and representative can finishes to verify detection, false reject and secure removal. Retain measured evidence for defect library and severity limits and challenge, reject and audit method with method, sample position, limit, deviation, witness, approval and review trigger. Use representative can and end lots, position-stratified seam teardown and integrity tests, controlled fill and pressure measurements, defect challenges, coating and corrosion review, thermal and distribution conditioning, and material-to-pallet traceability. Put the sample or test material, method, instrument, production state, duration, limit, witnesses, retained record and deviation authority in the protocol before testing begins. Requalify when a product, package, site, speed or connected system invalidates the accepted basis.