Controlled duty
Define diameter, length, fittings, elevation, insulation, support, slope, drainability, expansion and instrument positions from validated minimum holding requirement, flow envelope and product rheology. The review must also reconcile authority-defined minimum exposure requirement with flow, density and rheology envelope across normal, transition and fault conditions.
- Authority-defined minimum exposure requirement
- Flow, density and rheology envelope
- Required result and acceptable operating range