04 / Acceptance and handover
Prove the result under a representative production condition
Challenge high, low and unmixed intermediate states, verify blocked progression, representative sample, authorised adjustment, remix, resample and consistent final composition. Reconcile sweetener and water mass, trend concentration and temperature, challenge recipes and transitions, and verify released syrup, losses, residues and cycle performance. Put the sample or test material, method, instrument, production state, duration, limit, witnesses, retained record and deviation authority in the protocol before testing begins. Requalify when a product, package, site, speed or connected system invalidates the accepted basis.