04 / Acceptance and handover
Prove the result under a representative production condition
Calibrate the complete measurement loop, challenge clean, loaded and blocked states, and verify trend, alarms, terminal action, no bypass, investigation and media disposition. Challenge representative feed and operating limits, measure separation outcome and yield, verify integrity and bypass protection, and document fouling, cleaning and recovery performance. Put the sample or test material, method, instrument, production state, duration, limit, witnesses, retained record and deviation authority in the protocol before testing begins. Requalify when a product, package, site, speed or connected system invalidates the accepted basis.